Situation
    Any feedback on following would be appreciated. Pt. has PICC placed in CA junction and subsequently a surgeon unsucessfully attempts to place IVC filter. Followup xray shows PICC in right subcavian(with left basilic access). PICC was originally placed to the hub and remains so despite PICC position. Power flushing to reposition failed which brings up my question. If pt. is draped and arm is prepped with chlorhexidine can catheter be rewired with navion wire and repositioned? I told attending once catheter is pulled out it can not be reinserted and he wondered why not if done under sterile environment? Thanks in advance for your input.
Stephen Harris, CRNI
Lynn Hadaway, M.Ed., RN, NPD-BC, CRNI
Lynn Hadaway Associates, Inc.
PO Box 10
Milner, GA 30257
Website http://www.hadawayassociates.com
Office Phone 770-358-7861
Lynn Hadaway, M.Ed., RN, NPD-BC, CRNI
Lynn Hadaway Associates, Inc.
PO Box 10
Milner, GA 30257
Website http://www.hadawayassociates.com
Office Phone 770-358-7861
Thankyou. I have shared my concern for infection with this Doc. (and these post's) and he gets it now. Just wanted some back-up.
Stephen Harris CRNI